Chapter 1: Preparation for installation
5
1.2 Planning the installation
This section provides information and advice for planning the installation of your 
Display.
EMC Installation Guidelines
All Raymarine equipment and accessories are designed to the best industry standards 
for use in the recreational marine environment.
Their design and manufacture conforms to the appropriate Electromagnetic 
Compatibility (EMC) standards, but correct installation is required to ensure that 
performance is not compromised. Although every effort has been taken to ensure that 
they will perform under all conditions, it is important to understand what factors could 
affect the operation of the product.
The guidelines given here describe the conditions for optimum EMC performance, but 
it is recognized that it may not be possible to meet all of these conditions in all 
situations. To ensure the best possible conditions for EMC performance within the 
constraints imposed by any location, always ensure the maximum separation possible 
between different items of electrical equipment.
For optimum EMC performance, it is recommended that wherever possible:
• Raymarine equipment and cables connected to it are:
• At least 3 ft. (1 m) from any equipment transmitting or cables carrying radio sig-
nals e.g. VHF radios, cables and antennas. In the case of SSB radios, the distance 
should be increased to 7 ft. (2 m).
• More than 7 ft. (2 m) from the path of a radar beam. A radar beam can normally 
be assumed to spread 20 degrees above and below the radiating element.
• The equipment is supplied from a separate battery from that used for engine start. 
Voltage drops below 10 V, and starter motor transients, can cause the equipment 
to reset. This will not damage the equipment, but may cause the loss of some infor-
mation and may change the operating mode.
• Raymarine specified cables are used. Cutting and rejoining these cables can com-
promise EMC performance and must be avoided unless doing so is detailed in the 
installation manual.
• If a suppression ferrite is attached to a cable, this ferrite should not be removed. If 
the ferrite needs to be removed during installation it must be reassembled in the 
same position.