Symptom 1: The STATUS LED stays off after turning on the router.
Troubleshooting: The STATUS LED should stay solid on after powered on. The OFF 
status indicates that the MIM-HNDE module or some hardware is not powered on 
properly. Check the connection of the power supply.
If the device is powered on, the failure may due to the damaged power supply of 
the module, or abnormal operation of CPLD (Complex Programmable Logic 
Device). In these circumstances, contact our agents for support.
Symptom 2: The ACTIVE LED stays off when powering on the router.
Troubleshooting: When powering up the device, the ACTIVE LED should flashing 
for two seconds before turning off, which indicates the encryption processor of 
the MIM-HNDE module has been configured and is ready for work. If the ACTIVE 
LED stays on when powering up the device, this means the initialization of the 
processor fails and the system bus does not work normally. Check the connection 
between the MIM-HNDE module and the host. If the connection is good, the 
abnormal status may due to the host or the MIM-HNDE module, contact our 
agents for support.
Symptom 3: The ACTIVE LED stays on or off when the MIM-HNDE module is 
running.
Troubleshooting: The ACTIVE LED should be blinking when the MIM-HNDE 
module runs the encryption service. The solid on or off indicates the system bus 
works abnormally. Check the connection between the MIM-HNDE module and 
host. If the connection is good, the abnormal status may due to the host or the 
MIM-HNDE module, contact our agents for support.
MIM-2VE1 Module
Introduction
2-port E1 voice interface module (MIM-2VE1) can handle dense voice signals in 
VoIP system. It provides two CE1/PRI/R2 ports, allowing the access of 60 channels 
of voice signals.
Table 77   Description of the LEDs on the MIM-HNDE panel
LED Indication 
STATUS 
ON (green): The MIM-HNDE module is 
powered on properly.
OFF: There is no power supply, damaged 
power supply, or sever hardware failure. 
ACTIVE 
OFF after flashing yellow for two seconds: 
Initialized the MIM-HNDE module.
Blinking continuously: The MIM-HNDE 
module operates normally and there is 
data transmission with the host.
OFF: MIM-HNDE module runs normally and 
no data transmission exists with the host.