3com SuperStack 3 NBX Manual De Usuario
292
C
HAPTER
5: S
YSTEM
C
ONFIGURATION
Verifying a Failed
Disk Drive
If either disk fails while in a fully mirrored state, the system continues to
operate. The disk LED states described in
operate. The disk LED states described in
indicate which drive
has failed. In addition, the Disk Status window in NBX NetSet shows the
status of your disk drives.
status of your disk drives.
To verify the status of a disk drive, select Reports > System Data > Disk
Status. See the Help for information on verifying disk status.
Status. See the Help for information on verifying disk status.
Boot process completed, system initializing
Flashing
N/A
N/A
On
System is running
On
N/A
N/A
On
Flash codes indicate disk problem:
■
2 flashes: No valid disk (system is halted)
■
3 flashes: Two valid disks, but they are not
paired (system is halted)
paired (system is halted)
■
4 flashes: Configuration problem (system is
halted)
halted)
■
5 flashes: Two disks present, but no
mirroring license
mirroring license
N/A
Flashing Flashing
On
Using disk 0 (zero) only
N/A
On
Off
On
Using disk 1 only
N/A
Off
On
On
Synchronizing — disk 0 is valid, disk 1 is
becoming a fully mirrored disk. LED 3 flash rate
indicates progress.
becoming a fully mirrored disk. LED 3 flash rate
indicates progress.
If LED 3 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
flashes twice, the mirroring process has failed.
N/A
On
Flashing
On
Synchronizing — disk 1 is valid, disk 0 is
becoming a fully mirrored disk. LED 2 flash rate
indicates progress.
becoming a fully mirrored disk. LED 2 flash rate
indicates progress.
If LED 2 stops normal flashing and intermittently
flashes twice, the mirroring process has failed.
flashes twice, the mirroring process has failed.
N/A
Flashing
On
On
LED 2 and LED 3 flash alternately: the two disks
are resynchronizing
are resynchronizing
N/A
Flashing Flashing
On
Synchronized
N/A
On
On
On
Table 59 Disk LED States (continued)
Explanation
LED 1
LED 2
LED 3
PWR