3com SuperStack 3 NBX Manual De Usuario

Descargar
Página de 466
292
C
HAPTER
 5: S
YSTEM
 C
ONFIGURATION
Verifying a Failed
Disk Drive
If either disk fails while in a fully mirrored state, the system continues to 
operate. The disk LED states described in 
 indicate which drive 
has failed. In addition, the Disk Status window in NBX NetSet shows the 
status of your disk drives.
To verify the status of a disk drive, select Reports > System Data > Disk 
Status
. See the Help for information on verifying disk status.
Boot process completed, system initializing
Flashing
N/A
N/A
On
System is running
On
N/A
N/A
On
Flash codes indicate disk problem:
2 flashes: No valid disk (system is halted)
3 flashes: Two valid disks, but they are not 
paired (system is halted)
4 flashes: Configuration problem (system is 
halted)
5 flashes: Two disks present, but no 
mirroring license
N/A
Flashing Flashing
On
Using disk 0 (zero) only
N/A
On
Off
On
Using disk 1 only
N/A
Off
On
On
Synchronizing — disk 0 is valid, disk 1 is 
becoming a fully mirrored disk. LED 3 flash rate 
indicates progress.
If LED 3 stops normal flashing and intermittently 
flashes twice, the mirroring process has failed.
N/A
On
Flashing
On
Synchronizing — disk 1 is valid, disk 0 is 
becoming a fully mirrored disk. LED 2 flash rate 
indicates progress.
If LED 2 stops normal flashing and intermittently 
flashes twice, the mirroring process has failed.
N/A
Flashing
On
On
LED 2 and LED 3 flash alternately: the two disks 
are resynchronizing
N/A
Flashing Flashing
On
Synchronized
N/A
On
On
On
Table 59   Disk LED States (continued)
Explanation
LED 1
LED 2
LED 3
PWR