Parameter 
timer-name:  Name of Q931 timer. Refer to the following table for a description in 
detail. 
time-interval: Interval of timer. Refer to the following table for a description in detail. 
all: To be used to restore the default interval values of all the Q931 timers. 
Description 
Using the isdn q931-timer command, you can configure the interval for a Q931 
signaling timer. Using the undo isdn q931-timer command, you can restore the 
default interval values of Q931 signaling timers.   
Different timers have different default values. Refer to the following table for a 
description in detail. 
Table 6-2 Description of Q931 timers 
timer-name 
Timer 
Value range (in seconds) 
Default value (in seconds) 
t301 
T301 30–1200 
180 
t302 
T302 5–60 
15 
t303 
T303 2–10 
t304 
T304 10–60 
30 
t305 
T305 4–30 
30 
t308 
T308 2–10 
t309 
T309 10–180 
90 
t310 
T310 10–180 
30 
t313 
T313 2–10 
t316 
T316 20–180 
120 
t322 
T322 2–10 
 
Example 
Set the timer T322 to 6 seconds. 
[3Com-Serial2:15]isdn q931-timer t322 6 
6.9  isdn spid auto-trigger 
Syntax 
isdn spid auto-trigger 
View 
ISDN BRI Interface view 
3Com Router Command Reference Guide Addendum for V1.2
95