3com 4210G Manual De Usuario

Descargar
Página de 78
 
3-20 
Configure the physical connection mode 
IRF supports two physical connection modes: daisy chain connection and ring connection.  
A ring connection is more reliable than a daisy chain connection. The failure of one link in a ring 
connection does not affect the function and performance of the IRF, whereas the failure of one link in a 
daisy chain connection causes the split of the IRF. 
Figure 3-25 
The daisy chain connection mode 
IRF
Master
Slave 
Slave 
 
 
Figure 3-26 
The ring connection mode 
 
 
 
Each of the devices comprising a ring connection or non-edge devices in a daisy chain connection 
needs two 10 GE ports to connect other devices; therefore, you need to install two 1-port 10 GE XFP 
interface modules on such devices.  
 
Connect the cables 
Before connecting the cables, determine the actual position of the member devices and the length of 
the cables, and observe the following: 
z
 
Understand the neighbor devices for one another 
z
 
Install the interface modules in proper slots as needed. Each Switch 4210G provides two 
expansion slots.  
z
 
Determine the ports on different devices to be connected.  
Note that: