Ethertype | VID |123456789012345678901234567890123456789012
---------------------------------------------------------------
0x0800 5 .p........................................
0x0900 6 ...p......................................
SWITCH(bridge)#
With above configuration, the packets from port number 2 and 4 are decided according to
the protocol. In case the protocol is incongruous, the route is decided according to the
port based VLAN.
the protocol. In case the protocol is incongruous, the route is decided according to the
port based VLAN.
[Sample Configuration 4] Configuring QinQ
10 port of SWITCH 1 and 11 port of SWITCH 2 are connected to the network where dif-
ferent VLANs are configured. To communicate without changing VLAN configuration of
SWITCH 1 and SWITCH 2 which communicate with PVID 10, configure it as follows.
ferent VLANs are configured. To communicate without changing VLAN configuration of
SWITCH 1 and SWITCH 2 which communicate with PVID 10, configure it as follows.
You should configure the ports connected to network communicating with PVID 11 as
Tagged VLAN port.
Tagged VLAN port.
< SWITCH 1 >
SWITCH(bridge)# vlan dot1q-tunnel enable 10
SWITCH(bridge)# vlan pvid 10 11
SWITCH(bridge)# show vlan dot1q-tunnel
Tag Protocol Id : 0x8100 (d: double-tagging port)
----------------------------------------------------
| 1 2 3 4
Port |123456789012345678901234567890123456789012
----------------------------------------------------
dtag .........d................................
SWITCH(bridge)#
< SWITCH 2 >
SWITCH(bridge)# vlan dot1q-tunnel enable 11
SWITCH(bridge)# vlan pvid 11 11
SWITCH(bridge)# show vlan dot1q-tunnel
Tag Protocol Id : 0x8100 (d: double-tagging port)
----------------------------------------------------
| 1 2 3 4
Port |123456789012345678901234567890123456789012
----------------------------------------------------
dtag ..........d...............................
SWITCH(bridge)#
[Sample Configuration 5] Configuring Shared VLAN with FID
Configure br2, br3, br4 in the hiD 6615 S223/S323 configured Layer 2 environment and
24 ports as Uplink port is configured. To transmit untagged packet through Uplink port
rightly, follow below configuration.
24 ports as Uplink port is configured. To transmit untagged packet through Uplink port
rightly, follow below configuration.