GarrettCom 6K32FRC Manual De Usuario

Descargar
Página de 75
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 
 
66 
www   GarrettCom   com
.
.
 
Note: The GND should be hooked up first. The 6K32F unit has a floating ground, so 
the user may elect to Ground either + or - terminal to suit the customer’s use. 
 
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 
125VDC,  always use a digital voltmeter to measure the output voltage of the power 
supply and determine the lead which is  more  “+ve potential”. The more “+ve” voltage 
lead from 48V  or –48V supply must be connected to the post labeled “+”. 
 
 
An ON-OFF manual switch is optional for DC power. This can be used to cut 
off power connections and as a RESET for the Magnum 6K32F Series Switch. 
B4.1   
UL Requirements for DC-powered units 
1.   Minimum 18AWG cable for connection to a Centralized DC power source. 
2.   Minimum 14AWG cable for connection to a earthing wiring. 
3.   Use only with Listed 10 A circuit breaker provided in building installation. 
4.   “Complies with FDA radiation performance standards, 21 CFR subchapter J.” 
or equivalent. 
5.   Fastening torque of the lugs on the terminal block:  9 inch-pound max. 
6.   Centralized DC Power Source cable securement, use at least Minimum 14AWG 
four cable ties to secure the cable to the rack at least 4 inches apart, with the 
first one located within 6 inches of the terminal block.
 
B5.0 OPERATION 
 
Operation of Magnum 6K32F Series Switches with the optional -48VDC, 
24VDC and 125VDC power supply is identical to that of the standard AC-powered 
models. 
   
B6.0 ORDERING 
INFORMATION 
 
To order the optional -48VDC power supply factory installed, add a suffix of 
 “-48VDC” after the product’s standard model # Example: Magnum 6K32F-48VDC. 
 
Similarly to order the optional 24VDC or 125VDC industrial specific power 
supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s 
standard model #.   Example: Magnum 6K32F- 24VDC, Magnum 6K32F-125VDC. 
 
B7.0 TROUBLESHOOTING 
 
Please refer to Section 6.0 for troubleshooting