GarrettCom DX40 Manual De Usuario
C
HAPTER
2 - Installation
Installation of the DX40 Unit
DX40 Serial Device Router Installation Guide
16
Figure 2-5. Ground and Power Connections
Making the Ground Connection
The ground wire should be 14 AWG terminated with a #6 ring lug.
Make the facility ground connection as follows:
1. Loosen the ground screw on the chassis, insert the #6 ring lug, and tighten the
ground screw.
2. Connect the other end of the ground wire to the facility ground.
ELECTRICAL WARNING: Verify that a proper ground connection is made from the
grounding screw to facility ground prior to connecting power to the DX40. Failure to have
a proper ground path could cause serious injury or death to personnel in cases of power
surges.
grounding screw to facility ground prior to connecting power to the DX40. Failure to have
a proper ground path could cause serious injury or death to personnel in cases of power
surges.
non-polarized
90-250V
~ or
0.2A;50-60Hz
Serial No:
0650 0034
DX40-01-H-D
Non-polarized power input.
Grounding screw