Polycom 4300T Manual De Usuario

Descargar
Página de 118
User Guide V
2
IU 4300T Converged Network Appliance
3 - 24
1.
Select the Enable SNMP v1 or v3 checkbox.  If using SNMPv1 enter the 
Read-Only Community.  If using SNMPv3 enter the User Name, 
Passphrase and Security method.
2.
Enter the System Location.
This is a comment string that can be used to indicate the physical location 
of the 4300T.  By default, no value is set. 
3.
Enter the System Contact.
This is the administrative contact information for the 4300T.  By default, 
no value is set. 
4.
Enter the SNMP Port.
This is the port that the 4300T uses for SNMP communications with the 
network management system.  The default is 161. 
5.
Press Submit.
Disable SNMP
1.
Select System.
2.
Select System Overview.
3.
Select Services Configuration.
4.
Uncheck the Enable SNMP checkbox.
5.
Press Submit.
Configure Remote System Logging
The 4300T can be configured to log system messages to an external syslog 
server.
1.
Select the Enable Remote System Logging checkbox.
2.
Enter the IP address of the Remote Syslog Host.
By default messages are sent to the remote host on port 514.  This port can 
be changed by using the syntax ADDRESS:PORT. 
3.
Press Submit.
Disable Remote System Logging
1.
Select System.
2.
Select System Overview.
3.
Select Services Configuration.