RAD Data comm ASMi-52 Manual De Usuario

Descargar
Página de 186
Installation and Operation Manual 
Chapter 6  Troubleshooting and Diagnostics 
ASMi-52 Ver. 2.5 
Monitoring Performance 
6-7 
Table 6-2.  .  E1 Statistics Parameters (Cont.) 
Display Description 
Range 
Current DM 
Number of degraded minutes in which the BER exceeded 1×10
-6
. This 
value is updated every minute for 15-minute interval or every 24 hours for 
24-hour interval.  
0–1440 0–1440 
BPV last 
minute 
Number of bipolar violation events detected in the last minute. This value 
is updated every minute. 
0–1000 0–1000 
BPV max 
minute 
Number of bipolar violation events detected in the worst minute since the 
last resetting of the BPV counter. This value is updated every minute. 
0–1000 0–1000 
Current 
TIMER 
Time in seconds from the beginning of the interval. This value is updated 
every second. 
For 24-hour interval – number of 15 minutes intervals the device has been 
working after power up 
0–900 0–96 
Displaying E1/T1 Statistics for All Intervals 
You can display detailed E1/T1 performance statistics for 96 last 15-minute 
intervals elapsed since the last power-up. 
 
To display E1/T1 statistics for all intervals: 
1.  From the E1 Port Performances menu, select E1/T1 All Intervals Local 
Performances 
or E1/T1 All Intervals Remote Performances (Main menu > 
Monitoring > Physical Ports Statistics > E1/T1 Port Performances > E1/T1 All 
Intervals Local/Remote Performances) to display the E1/T1 statistics for all 15-
minute intervals. 
The E1/T1 All Intervals Local/Remote Performances screen appears (see 
Figure 6-10
). 
2.  Press any key to exit the E1/T1 All Intervals Local/Remote Performances 
screen. 
ASMi-52 
E1/T1 all intervals local/remote performances ... 
 
 INTERVAL  ES  SES  UAS  BES  LOFC  CSS  DM 
 
ESC-prev. menu; !-main menu; &-exit; @-scroll; ?-help 
Figure 6-10.  E1/T1 All Intervals Local/Remote Performances