Appendix A  Interface Connector Specifications 
Installation and Operation Manual 
A-2 
DTE Interface Connectors 
ASMi-52 Ver. 2.5 
Table A-1.  V.35, X.21 and RS-530 Connector Pinouts (Cont.) 
V.35 
RS-530 
X.21 
Description 
34-Pin  
DB-25  
DB-15  
 
Signal 
Function 
Pin 
Circuit 
Pin 
Circuit 
Pin 
 
Circuit  
(Function) 
 
Data Set 
Ready 
E DSR 
107 
22 
CC(A) 
CC(B) 
 
 
A positive level from ASMi-52 
when power is on, and ASMi-52 
is (a) not in DIGITAL LOOP 
mode, or (b) has not received a 
REMOTE LOOPBACK signal 
from the remote unit.  
Data 
Terminal 
Ready 
H DTR 
108 
20 
23 
CD(A) 
CD(B) 
  
Not 
used 
Carrier 
Detect 
F DCD 
109 
10 
CF(A) 
CF(B) 
12 
 
I(A) 
I(B) 
(Indication) 
A positive level from ASMi-52, 
except when a loss of the 
received signal is detected or 
when Data Set Ready is 
negative. 
External 
Transmit 
Clock 
SCTE(A) 113  
SCTE(B) 113 
24 
11 
DA(A) 
DA(B) 
14 
(A) 
(B) 
A serial data rate clock input 
from the data source. Positive 
clock translations must 
correspond to data 
transmissions. 
Transmit 
Clock 
SCT(A) 114 
SCT(B) 114 
15 
12 
DB(A) 
DB(B) 
13 
 
S(A) 
S(B) 
(Signal 
Timing) 
A transmit data rate clock for 
use by an external data source. 
Positive clock translations 
correspond to data translations. 
Receive 
Clock 
SCR(A) 
115 
SCR(B) 
115 
17 
DD(A) 
DD(B) 
 
 
A receive data rate clock output 
used by an external data sink. 
Positive clock translations 
correspond to data translations. 
Local Analog 
Loop 
L and j 
18 
LL 
 
A control signal input, which, 
when on, sets ASMi-52 into 
Local Analog Loopback (V.54 
Loop 3). 
Remote 
Digital Loop 
N and h 
21 
RL 
 
A control signal input which, 
when on, commands  
ASMi-52 to send a remote 
Loopback command (V.54 Loop 
2) to the remote ASMi-52. 
Test 
Indicator 
n and k 
25 
TM 
 
A Control Signal output from  
ASMi-52; positive during any 
test mode.