Installation and Operation Manual 
Chapter 4  Configuration 
ASMi-52 Ver. 2.5 
Configuring the Physical Ports 
4-35 
•  Transmit signal mask (DSU mode) – length of a cable in feet between the  
ASMi-52 T1 port connector and the network access point:  
 
0 feet 
– 0 to 133 feet 
 
133 feet 
– 133 to 266 feet 
 
266 feet 
- 266 to 399 feet 
 
399 feet 
– 399 to 533 feet 
 
533 feet 
– 533 to 655 feet 
•  Transmit signal mask (CSU mode) – relative T1 output transmit level: 
 
7.5 dB 
– attenuation of 7.5 dB relative to the nominal transmit level 
 
15 dB 
– attenuation of 15 dB relative to the nominal transmit level 
 
22.5 dB 
– attenuation of 22.5 dB relative to the nominal transmit level 
•  Fbit configuration – Fbit transmission mode:  
 
Transparent 
– F bits are sampled at TSER 
 
Internally Source 
– F bits are sourced internally. 
• 
 
Configuration of the sync mode, idle mode, timeslot assignment and matching of T1 
setting of the local and remote units (Unit Identical Set) is identical of that of the E1 
interface. Refer to 
Configuring the E1 Interface
 section above. 
 
 
To access the T1 Configuration menu: 
1.  From the Configuration menu, select T1 Configuration
The T1 Configuration menu appears. 
2.  From the T1 Configuration menu, select T1 local port for the local port 
configuration or select T1 remote port for the remote port configuration. 
The T1 Local/Remote Configuration menu appears (see 
Figure 4-37
). 
ASMi-52 
T1 Local Port Configuration 
1. Framed Mode   
>(SF) 
2. Line code 
 
 (B8ZS/AMI) 
3. Receive Gain  
 (LONG/SHORT) 
4. Interface 
 
>(DSU/CSU) 
5. Transmit Signal Mask 
 (7.5 dB) 
6. Fbit Configuration 
 (Transparent/Internally Source) 
7. Sync Mode 
 
 (FAST) 
8. Units identical setting   (Yes/No) 
9. Idle code 
 
 (ff) 
10. Time slots assign 
11. Save 
 
>  
ESC-prev. menu; !-main menu; &-exit;  
 
Figure 4-37.  T1 Port Configuration 
 