Log parameters
 
Description of last fault log
Code
Description
dP0
Parameter name:
Fault code on last fault
Logic address:
7200 = 16#1C20
Type:
WORD (listing)
CANopen index:
202A/1
Read/write:
R
INTERBUS index:
5FB9/59
Unit:
-
DeviceNet path:
85/01/01
Value of the "Altivar fault code" 
(LFt)
 parameter, written to memory when the last fault occurred.
See the possible values of the "Altivar fault code" 
(LFt)
 parameter.
ULP0
Parameter name:
Power supply voltage on last fault
Logic address:
7270 = 16#1C66
Type:
UINT
CANopen index:
202A/47
Read/write:
R
INTERBUS index:
5FB9/98
Unit:
0.1 V
DeviceNet path:
85/01/47
Value of the "Power supply voltage" 
(ULn)
 parameter, written to memory when the last fault occurred.
LCP0
Parameter name:
Motor current on last fault
Logic address:
7240 = 16#1C48
Type:
INT
CANopen index:
202A/29
Read/write:
R
INTERBUS index:
5FB9/7D
Unit:
0.1 A
DeviceNet path:
85/01/29
Value of the "Motor current" 
(LCr)
 parameter, written to memory when the last fault occurred.
rFP0
Parameter name:
Output frequency on last fault
Logic address:
7250 = 16#1C52
Type:
INT
CANopen index:
202A/33
Read/write:
R
INTERBUS index:
5FB9/86
Unit:
0.1 Hz
DeviceNet path:
85/01/33
Value of the "Output frequency" 
(rFr)
 parameter, written to memory when the last fault occurred.
tHP0
Parameter name:
Motor thermal state on last fault
Logic address:
7280 = 16#1C70
Type:
UINT
CANopen index:
202A/51
Read/write:
R
INTERBUS index:
5FB9/A1
Unit:
DeviceNet path:
85/01/51
EP0
Parameter name:
Status word on last fault
Logic address:
7210 = 16#1C2A
Type:
WORD (bit register)
CANopen index:
202A/B
Read/write:
R
INTERBUS index:
5FB9/62
Unit:
-
DeviceNet path:
85/01/0B
Value of the "Status word" 
(EtA)
 parameter, written to memory when the last fault occurred.
See the possible values of the "Status word" 
(EtA)
 parameter.