Log parameters
 
110
Format of "Date" and "Time" parameters
Date and time are binary-coded using the corresponding word bits indicated in the table below. 
Note: The value 0 for year corresponds to the year 2000 (2006 = 36, for example).
Bits
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Date
Year
X
X
X
X
X
X
X
Month
X
X
X
X
Day
X
X
X
X
X
Time
Hours
X
X
X
X
X
X
X
X
Minutes
X
X
X
X
X
X
X
X