Chapter 3  Operation 
IPmux-16 Installation and Operation Manual 
3-42 Configuring IPmux-16
 
 
Table 3-3.  Alarms and Statistics (Cont.) 
Alarm 
Failure 
Comments 
Valid in X only 
SES 
Severely Errored Seconds. 
Any second containing the 
following errored events is 
counted as severely errored 
seconds: 
 
  
For 
E1/T1: 
If 320 or more CRC error events 
One or more SEF (OOF) events  
One or more AIS events 
occurred (for T1 only). 
 
UAS 
Unavailable Seconds: 
Activated when there are 10 
consecutive SES occurrences 
and 
Deactivated as a result of 10 
consecutive seconds without 
SES.  
 
LOMF 
 
Loss Of Framing sequence in 
Time Slot 16 
 
The E1/T1 Physical Layer Menu allows you to monitor the following  
Time Since
: The elapsed time since the beginning of the current interval  
(interval 0). Displayed only when the current interval is monitored. 
Valid Intervals
:  The number of 15 minute intervals stored in the system since 
power up. 
Slot/Channel:  
Select the E1/T1 module and channel on which you want to view 
statistics  
Interval Number
:  The number of the interval to be displayed. 
Interval number 0 (zero) is the current interval. 
The current interval display is continuously updated.  
The elapsed time since the beginning of the interval is displayed. 
Prev Inv:  
Displays the previous interval.  
From the first interval (current interval = 0) Prev is not visible 
Next Inv:  
Displays the next interval.  
The number of valid intervals is displayed.  
From the last valid interval Next is not visible.