Transition Networks MIL-SM2401MAF Manual De Usuario

Descargar
Página de 111
Transition Networks                                                                                                                  MIL-SM2401MAF 
 
24-Hour Technical Support: 1-800-260-1312                                                  International: 00-1-952-941-7600 
                                                                               
 
11
 
2.  Remove adhesive backing from the Rubber Pads.   
3.  Apply  the  Rubber  Pads  to  each  corner  on  the  bottom  of  the  switch.  These 
footpads can prevent the switch from shock/vibration. 
 
Rack-mounted Installation 
 
The switch come with a rack-mounted kit and can be mounted in an EIA standard size, 
19-inch Rack. The switch can be placed in a wiring closet with other equipment.   
Perform the following steps to rack mount the switch: 
 
1.  Position one bracket to align with the holes on one side of the switch and secure it 
with  the  smaller  bracket  screws.  Then attach  the  remaining  bracket  to  the  other 
side of the switch. 
2.  After  attaching  both  mounting  brackets,  position  the  24  10/100TX  plus  2 
Mini-GBIC/Copper managed PoE switch in the rack by lining up the holes in the 
brackets with the appropriate holes on the rack. Secure the switch to the rack with 
a screwdriver and the rack-mounting screws. 
 
[Note] For proper ventilation, allow about at least 4 inches (10 cm) of clearance on 
the  front  and  3.4  inches  (8  cm)  on  the  back  of  the  switch.  This  is  especially 
important for enclosed rack installation. 
 
 
Power On   
 
Connect the power cord to the power socket on the rear panel of the switch. The other 
side  of  power  cord  connects  to  the  power  outlet.  The  internal  power  supply  of  the 
Switch works with AC voltage range of 100-240V and Frequency of 50~60Hz. Check 
the power indicator on the front panel to see if power is properly supplied.