GE GFK-1004B Manual De Usuario

Descargar
Página de 268
 5
5-35
GFK-1004B
Chapter 5  The Station Manager
STOPP Command
The STOPP command has the form:
STOPP
This command causes an active PING sequence to stop at its next iteration and to print
the results of the terminated test.  It is used to terminate a long running PING sequence.
STOPT Command
The STOPT command has the form:
STOPT
This command causes an active TEST sequence to stop at its next iteration and to print
the results of the terminated test.  It is used to terminate a long running test before its
completion.
A typical STOPT command is shown below:
= stopt
Test stopped by operator
=                                                              Page 1 of 1
<<< Test Results >>>
Command: test <<0800190100fb>> 100H 32H 0H NULL
Init node: <<08001901001f>>  Frames sent : 87H  Nodes responding : 1H
Responding nodes   Response recd   Response w/err   No Response
<<0800190100fb>>     87H              0H                  0H