Table 8-1 Menu 11.1 Remote Node Profile 
FIELD DESCRIPTION 
EXAMPLE 
Telco 
Options: 
Transfer 
Type 
 
This field specifies the type of connection between the Prestige and this 
remote node. When set to Leased, the Allocated Budget and Period do 
not apply. 
 
64k 
Allocated 
Budget (min) 
This field sets a ceiling for outgoing call time for this remote node. The 
default for this field is 0 for no budget control. 
Default = 
Period (hr)  This field sets the time interval to reset the above outgoing call budget 
control. 
 
Schedules  Apply up to 4 schedule sets, separated by commas to your remote node 
here. Please see ahead for a full discussion on schedules. 
 
Carrier 
Access Code 
In some European countries, you need to enter the access code number 
of your preferred telecommunications service provider. Your telephone 
company should supply you with this number. 
 
Nailed-up 
Connection 
This field specifies if you want to make the connection to this remote 
node a nailed-up connection. See the following section for more details. 
No 
Toll Period  This is the basic unit of time for charging purposes, e.g., 25 cents every 3 
minutes – 3 minutes is the Toll Period. 
 
Session 
Options: 
Edit Filter 
Sets 
Press [SPACE BAR] and then [ENTER] to select Yes to open Menu 11.5 
to edit the filter sets. See the Remote Node Filter section for more details. 
Default = No 
Idle Timeout 
(sec) 
This value specifies the number of idle seconds that elapses before the 
remote node is automatically disconnected. Idle seconds is the period of 
time when no data is transmitted from your Prestige. Administrative 
packets such as RIP are not counted as data. The default is 300 seconds 
(5 minutes). Idle timeout only applies when the Prestige initiates the call. 
0 sec means the remote node will never be automatically disconnected. 
Default = 
300 secs 
When you have completed this menu, press [ENTER] at the prompt “Press ENTER to Confirm…” to save 