Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
9-12
August 2003
Access Navigator - Release 1.8
Provision DCS Service
Provision “Groom” DS1 Circuits to Network
Provision “Groom” DS1 Circuits to Network
1. Show groom DS1 settings with the following command:
show ds1 <n>
Example:
show ds1 10
The show command will produce a message showing the DS1 settings. For example, the message 
for DS1 number 10 might look similar to the following:
Settings for DS1 10:
  Circuit ID:            CA DS1# 10
  Up/Down:               DOWN
  Framing:               ESF
  Line Coding:           B8ZS
  Type:                  DROP
  Clock Source:          NORMAL
  Line Build Out:        DSX-1 EQUALIZATION FOR 0-133 ft.
  Loop Code Detection:   OFF
  Loop Back:             OFF
  Line Termination ID:   0 (for switch DS1s only)
  FDL Type:              CAC
  Send Code:             None
  Performance Thresholds:      15 min.    1 hour     1 day
                              --------   -------    ------
  unavailable seconds:               0         0         0
  severely errored seconds:          0         0         0
  errored seconds:                   0         0         0
  sev. errored frame seconds:        0         0         0
  degraded minutes:                  0         0         0
  linecode violations:               0         0         0
NOTE:  
In the above message loop back test function is turned off and the send code 
set to none during normal service. Line Termination IDs are used only for GR-303 switch 
DS1s.
2. If groom DS1 settings are correct, skip remaining steps.
3. Set DS1 type to “groom” with the following command:
set ds1 <n> type groom
Example:
set ds1 10 type groom
4. Set groom DS1 frame type to D4 or ESF with the following command:
set ds1 <n> framing <d4|esf>
Example:
set ds1 10 framing esf