Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
Access Navigator - Release 1.8
August 2003
11-15
 
Provision Remote Access Bank II
Provision Drop DS1 to Remote Access Bank II
Provision Drop DS1 to Remote Access Bank II
NOTE:  
This is the T1 connection between the Access Navigator and Access Bank II.
1. Show drop DS1 settings with the following command:
show ds1 <n>
Example:
show ds1 10
The show command will produce a message showing the DS1 settings. For example, the message 
for DS1 number 10 might look similar to the following:
Settings for DS1 10:
Circuit ID:
CA DS1# 10
Up/Down:
DOWN
Framing:
ESF
Line Coding:
B8ZS
Type:
DROP
Clock Source:
NORMAL
Line Build Out:
DSX-1 EQUAL. FOR 0-133 ft.
Loop Code Detection:
OFF
Loop Back
OFF
Line Termination ID:
0 (for switch DS1s only)
FDL Type:
CAC
FDL Status:
UP
Bit Error Rate:
2.31425e-4
NOTE:  
In the above message the loop back test function is turned off during normal 
service. Line Termination IDs are used only for GR-303 switch DS1s. FDL Status does not 
appear if FDL Type is none. Bit Error Rate appears only if test pattern is present.
2. If drop DS1 settings are correct, skip remaining steps.
3. Set DS1 type to “drop” with the following command:
set ds1 <n> type drop
Example:
set ds1 25 type drop
4. Set drop DS1 frame type to ESF with the following command:
set ds1 <n> framing esf
Example:
set ds1 25 framing esf
5. Set drop DS1 line code to B8ZS with the following command:
set ds1 <n> linecode b8zs
Example:
set ds1 25 linecode b8zs