Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
11-26
August 2003
Access Navigator - Release 1.8
Provision Remote Access Bank II
Configure Remote V.35 Interface (if used)
Configure Remote V.35 Interface (if used)
1. Show current remote interface settings with the following command:
show remote <n|all>
Example:
show remote 11
Example:
show remote all
The show command will display the remote interface settings the each DS1 specified, or for all 
DS1s. For example, the message for showing DS1 number 11 would look similar to the following:
Settings for remote device Remote Device #11:
     Remote Config:      enabled
     T1 Drop Port:
       Line Coding:      AMI
       Framing:          D4
       Line Build Out:   DSX-1 0-133 ft. (or 0 db)
       PRM:              AT&T
     V.35 Port:
       CTS:              Always High
       Rx Timing:        Internal
       Clock Inversion:  None
       Data Inversion:   Normal
       Speed:            Nx64
       DSU:              On
     RS232 Port:
       Baud Rate:        9,600
       Data Bits:        8
       Parity:           None
       Stop Bits:        1
2. If drop V.35 settings are correct, skip remaining steps.