Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
Access Navigator - Release 1.8
August 2003
13-21
 
Provision Remote Adit 600 via IP DS0
Provision DS0 Crossconnects
Provision DS0 Crossconnects
NOTE:  
Static DCS voice and data crossconnects, as well as ISDN BRI D (signaling) 
channels, must be provisioned in the Access Navigator. Crossconnects are not required 
for GR-303 voice and ISDN BRI B (bearer) channels because they are dynamically 
assigned by the switch.
1. Show current crossconnect settings with the following command:
show connect <n> 
Example:
show connect 10
The show command will display the current settings for the specified DS1. For example, the mes-
sage for DS1 number 11 would look similar to the following:
Connections for DS1 #10 (CA DS1# 10):
From    To    Type   Interface [--> Port]
----   -----  -----  --------------------
10:01  .....  GR303
10:02  .....  GR303
10:03  .....  GR303
10:04  .....  GR303
10:05  .....  GR303
10:06  .....  GR303
10:07  .....  GR303
10:08  .....  GR303
10:09  .....  GR303
10:10  .....  GR303
10:11  .....  GR303
10:12  .....  GR303
10:13  .....
10:14  .....
10:15  .....
10:16  .....
10:17  17:12  DATA   AcmeInternet --> V.35
10:18  17:13  DATA   AcmeInternet --> V.35
10:19  17:14  DATA   AcmeInternet --> V.35
10:20  17:15  DATA   AcmeInternet --> V.35
10:21  17:16  DATA   AcmeInternet --> V.35
10:22  17:17  DATA   AcmeInternet --> V.35
10:23  17:18  DATA   AcmeInternet --> V.35
10:24  32:10  DATA
NOTE:  
For IP DS0 management, it is recommended that the management channel be 
assigned to DS0 #24 on the drop DS1 to the remote Adit 600.
2. If DS0 crossconnect settings are correct, skip remaining steps.