Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
14-16
August 2003
Access Navigator - Release 1.8
Alarm Clearing
Power Status LEDs
Power Status LEDs
The Access Navigator may have one or two Controller cards. Each Controller card has a Power LED 
indicator showing the status of the -48 VDC input power as well as the status of the card’s internal 
power supply. 
Table 14-9. Power Status LEDs
LED State
Description
Troubleshooting
Green
Normal operation
Normal operation.
Off
-48V power failure or power 
missing
Check -48V input to unit. Input voltage 
must be between -42 and -60 V.
Red
Internal power supply failure
Power supply is located on Controller 
card. Replace suspect Controller card (A 
or B) with known good card. Cards can 
be replaced with power on.
Yellow
Card is booting up after reset 
or power-on.
If a software upgrade to version 1.20 or 
higher is performed on a standby 
Controller without a SIMM installed, the 
Controller’s POWER indicator will 
remain yellow until the required SIMM is 
installed