Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
18-56
August 2003
Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
Read Remote V35
Purpose:
Reads and displays the V.35 settings from the remote Access Bank II at the far end of 
the Access Navigator’s DS1. The Access Bank II must be operational to read its 
settings. The command displays a message similar to the following.
Security:
Level 3 (monitor)
Syntax:
read remote <n> v35
Example:
read remote 9 v35
Message:
  V35:
    datainv:  normal
    clkinv:   none
    cts:      high
    rxclk:    internal
    speed:    nx64
    dsu:      Off
    length:   4
Description:
Field
Description
n
DS1 number, 1 to 32.
Item
Description
datainv
Data polarity inversion: normal, invert
clkinv
Clock polarity inversion: none, invert
cts
Clear to Send signaling: always high, always low, follow cd, 
follow rts
rxclock
Receive clock source: internal, external
speed
Data speed (Kbps): Nx56 or Nx64, where N is length (number of 
DS0s)
dsu
V.54 Data Service Unit (DSU) loopcode detection: on, off
length
Number of DS0s assigned, 0 to 32