Syntax:
send remote <n> t1drop payload loopup
Example:
send remote 9 t1drop payload loopup
Message:
Loop command sent to remote.
Send Remote T1Drop TSI Loopup
NOTE:  
This command applies only to a remote Access Bank II connected 
to the Access Navigator by a DS1 using Carrier Access FDL management 
protocol. For normal operation, the loopback must be disabled by the send 
remote
 loopdown command.
NOTE:  
Only one port of the Access Bank II can be looped up at a time. If a 
loopup command is received for a second port, the first port will be looped down 
automatically before the second port is looped up.
NOTE:  
To check remote loopback status, use the read remote loopback 
Purpose:
Sends an out-of-band (FDL) message to a remote Access Bank II over the Access 
Navigator DS1. It is used to verify T1 Drop signal processing.
When the operator enters a send remote command, the Access Navigator transmits 
a message over the Carrier Access FDL management channel of the drop DS1. The 
Access Navigator’s drop DS1 is the Access Bank’s T1 connection.
The send remote t1drop tsi loopup command should cause the remote Access 
Bank II to perform a Time Slot Interface (TSI) loopback on the T1drop side. This takes 
the received T1drop DS0s, loops them in the TSI, and sends them back to the T1drop 
output (see Figure 18-20). To loopdown the interface, use the send remote loopdown 
command.
Field
Description
n
DS1 number, 1 to 32