Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
Access Navigator - Release 1.8
August 2003
18-121
 
CLI Language Reference
CLI Command List
Syntax:
set remote <nrs232 baud <setting>
Example:
set remote 9 rs232 baud 57600
Set Remote RS232 Data
Purpose:
Sets Access Bank II remote RS-232 interface data bits and parity.
Security:
Level 2 (operator)
Syntax:
set remote <nrs232 data <e7|o7|n8>
Example:
set remote 9 rs232 data n8
Set Remote RS232 Stop
Purpose:
Sets Access Bank II remote RS-232 interface stop bits.
Security:
Level 2 (operator)
Syntax:
set remote <nrs232 stop <1|2>
Example:
set remote 9 rs232 stop 1
Field
Description
n
DS1 number, 1 to 32
setting
Baud rate selections are:
1200, 2400, 4800, 9600, 19200, 38400, 57600
Field
Description
n
DS1 number, 1 to 32
e7
7 bit data, even parity
o7
7 bit data, odd parity
n8
8 bit data, no parity
Field
Description
n
DS1 number, 1 to 32.
1|2
Number of stop bits, 1 or 2.