Carrier Access Access Navigator Manual De Usuario
14-16
August 2003
Access Navigator - Release 1.8
Alarm Clearing
Power Status LEDs
Power Status LEDs
The Access Navigator may have one or two Controller cards. Each Controller card has a Power LED
indicator showing the status of the -48 VDC input power as well as the status of the card’s internal
power supply.
indicator showing the status of the -48 VDC input power as well as the status of the card’s internal
power supply.
Table 14-9. Power Status LEDs
LED State
Description
Troubleshooting
Green
Normal operation
Normal operation.
Off
-48V power failure or power
missing
missing
Check -48V input to unit. Input voltage
must be between -42 and -60 V.
must be between -42 and -60 V.
Red
Internal power supply failure
Power supply is located on Controller
card. Replace suspect Controller card (A
or B) with known good card. Cards can
be replaced with power on.
card. Replace suspect Controller card (A
or B) with known good card. Cards can
be replaced with power on.
Yellow
Card is booting up after reset
or power-on.
or power-on.
If a software upgrade to version 1.20 or
higher is performed on a standby
Controller without a SIMM installed, the
Controller’s POWER indicator will
remain yellow until the required SIMM is
installed
higher is performed on a standby
Controller without a SIMM installed, the
Controller’s POWER indicator will
remain yellow until the required SIMM is
installed