8-18
Broadmore 1750 - Release 4.6
Maintenance and Troubleshooting
Problem Isolation
Problem Isolation
Once you have determined that a problem exists, perform the following steps   to isolate 
the problem for repair:
1. Check to ensure power is available to all modules.
2. Review the LED displays to determine if any module is in an alarm state. 
Evaluate the alarms and isolate the problem to the extent possible.
3. Review the slot configuration and look at the individual ports. Evaluate any 
information to further isolate the problem.
4. Check wiring to ensure connected equipment cables are properly installed and 
secured. Do not assume the problem is internal to the Broadmore 1750.
5. Check module(s) Configuration from the System Management pull-down 
menu. Choose the slot of interest and verify that the configuration is correct for 
each port.
6. Use loopbacks (below) to pinpoint circuit connectivity problems.
7. Use the flowcharts that follow to pinpoint hardware problems.
Select System Management
 
Select Monitor
 
Select Slot
 
Select the slot of interest
 ↵
Select individual ports
 ↵
Observe Data