Security Management (FIPS Mode)
Enabling FIPS Mode
Enabling FIPS Mode
Only a Superuser (Crypto Officer) can change the security modes. The Broadmore 
is shipped from the factory with FIPS mode turned off. The security mode can only 
be changed after successfully logging into the Broadmore for the first time, by 
performing the following steps.
1. Log into the online CPU (Broadmore primary IP address) with a conventional 
terminal emulator such as Telnet (see “Logging In” on page
).
2. Enable FIPS mode by entering the following command at the Broadmore 
prompt:
fipsmode on 
3. Set the session timeout for the Broadmore craft port by entering the following 
command:
settimeout <hh:mm:ss> 
Example: settimeout 00:05:00 sets the timeout to 5 minutes.
The current value can be displayed by entering settimeout by itself.
NOTE:  
The SSH session timeout is fixed at 5 minutes.
Item
Comments
FIPS Mode Active
Broadmore is in FIPS 140-2 validated operating mode
Security inactive; 
non-FIPS mode
Broadmore is not in FIPS approved operating mode
FIPS Lib Rev
Version of FIPS Library.
SSHield
Version of SSHield software
Built
Build date of SSHield software