Installation
Cabling the Alarm Ports
Cabling the Clock Ports on the ITU Chassis
On the front panel of the chassis are two pairs of synchronization clock ports: CKIN-1 and CKOUT-1
and CKIN-2 and CKOUT-2 (one pair is redundant for the other). CKIN-1 and CKOUT-1 are 
connected to NSP-1, and CKIN-2 and 
CKOUT-2
 are connected to NSP-2.
Connect the CKOUT ports to provide the timing signal to a further piece of communications 
equipment. The CKIN-1CKOUT-1CKIN-2, and CKOUT-2 ports are 75ohm BNC connectors.
Cabling the Alarm Ports
The ALARMS port supports four alarm contact connections: two inputs and two outputs. These 
contacts can be used to provide additional external alarms (audible and visual) when an alarm occurs 
on the BROADway system as well as to collect alarms arriving from external sources.
The ALARMS port is a female, DB15 connector.
The ALARMS port provides two alarm sense inputs, and two alarm generation outputs.
!
Alarm sense #1 and #2 (alarm inputs)—These are used to collect alarms coming from an 
external source, such as other equipment, high water sensor, fire alarms, and so forth.
CKOUT-2
CKIN-2
NIP TX1
NIP TX2
TX2
TX1
TX3
CKOUT-1
TX4
NIP RX1
NIP RX2
RX3
RX1
RX2
RX4
CKIN-1
ALARMS
ACO
SCP-2
ETH-1
ETH-2
SCP-1
Connect a clock source
Connect a second clock source
CKIN-1
NIP TX1
NIP TX2
TX2
TX1
TX3
TX4
NIP RX1
NIP RX2
RX3
RX1
RX2
RX4
ALARMS
ACO
SCP-2
ETH-1
CKIN-2
ETH-2
SCP-1