Troubleshooting 5 - 5
Bridge Operation
Once your Bridge has passed the self-test and appears to be working, you 
may have some operating questions or problems.  Listed below are some 
common bridge operation problems and their solutions.
If you can't establish a connection between a node on the port 1 
subnetwork and one on the port 2 subnetwork, make sure the network 
software running on both nodes is compatible.  You should also view the 
FWD LED status on the front panel.  This LED should be lit when port 1 and 
port 2 are communicating.
The management prompt on the 
screen is not as you set it.
The Bridge Module is connected to a 
remote device or you did not save the 
new prompt.  Refer to the 
REMOTE_LOGIN and LOGOUT 
commands in Chapter 4.
The prompt >> appears on the 
screen.
The bridge is operating out of the 
Boot PROM code for the Bridge 
Module.  The Boot PROM code 
contains a subset of the operating 
code that is contained on the Flash 
EPROM.  Refer to Chapter 6, 
Firmware Download Instructions, for 
directions on booting up to the Flash 
EPROM version of the bridge code.
Table 5-3.  Management Interface Suggestions (Continued)
Problem
Troubleshooting Suggestions