All shields are connected to pin 1 and the AUI connector shell.  Pin 4 is not 
used.  Most Ethernet cables are built this way.
V1.0
Shielding of individual signal or power pairs is not required, since most V1.0 
con-trollers and transceivers are DC-coupled.  The overall AUI cable shield 
provides for shielding and grounding and is connected to pin 1 and the AUI 
connector shell.
In practice, most Ethernet V1.0 equipment uses version 2.0 cables due to 
cross-talk problems caused by the lack of individual shielding of the pairs in 
version 1.0 cables.
Wire Sizes
The three versions of AUI cables also use different wire sizes for the signal 
and power pairs. Table C-2 describes the wiring used by each type of 
transceiver cable.
Signal deterioration along the signal pairs is most likely to happen as the 
AUI cable approaches the maximum length of 40 meters.  This signal 
deterioration is due to the filtering action of the cable.  IEEE 802.3 AUI 
cables are designed to reduce this effect.
Table C-2.  Transceiver Cable Wire Sizes
Cable Type
Signal Pair
Power Pair
V1.0
AWG #22
AWG #20
V2.0 and IEEE 802.3
AWG #20
AWG #20
Non-standard “Office” cable *
AWG #24 *
AWG #24 *
* more flexible, but is limited to 5.0 meters in length.