3 - 12 ONline Ethernet Bridge Module Installation and Operation Guide
Note: Terminal values you set using the SET command are not 
saved permanently until you issue the SAVE TERMINAL 
command. Once the values are saved, if you log out or 
even if the power fails, the saved values are retained.
Automatic Modem Hangup
If you use a modem to connect to the Bridge Module, you may want to use 
the SET TERMINAL HANGUP command to hang up the modem connection 
automatically when you log out of the Bridge Module. The factory default 
is disable, which does not automatically hang up a modem. The following 
example shows the command used to automatically hang up the modem 
once you log out of the Bridge Module.
OEBM> set terminal hangup enable            [ENTER]
Note: If you fail to hang up the modem connection, an 
unauthorized user may pick up the last login session.
Configuring the Bridge Module
Now that the terminal settings are complete, you can configure the Bridge 
Module in the concentrator. We recommend that you complete the 
following steps when you log in for the first time:
1. Establish passwords
2. Configure other Bridge Module parameters
3. Set Bridge Module SNMP values
Establishing Passwords
Bridge Management provides a password-protection capability that allows 
you to control access to certain commands and information. You must be 
in administrator mode to be able to change passwords. Note that when 
you first log in the default password is [ENTER]. This default password will 
provide you with administrator privileges.