AccessIT 
50
 
Choose to display All 
Targets or just a 
particular Target set
Targets connected to 
the PDU outlets appear 
here
Double-click for Target to 
appear at the next available 
outlet or drag and drop to 
relevant outlet
 
Figure 46 Outlets tab 
Here you select and configure all Targets connected to the PDU ports. 
1.  From the Show Targets drop-down list choose to display all Targets or only the 
particular Target set that has servers connected to the PDU. The Targets appear 
in the list. You can search for a Target set by typing the Target set name in the 
field. 
2.  Double-click a Target from the Targets list to make it appear in the first 
available spot in the Ports list. For example if Target1 is connected to to port 1 
of the PDU, double-click Target1, etc. Drag and drop a Target to place it into 
any port number of the Ports list. E.g. if Target1 is connected to to port 7 of the 
PDU, drag and drop Target1 to port 7. 
3.  On completeion click Save. The PDU appears on the PDU page, see Figure 44. 
Also when clicking a Target on the Targets page, the configured PDU appears 
in the PDU tab, see Figure 27. Power management is operated through the PDU 
icon that appears next to the Target on the Access page, see page 108. 
9.2 Configuring Console Servers 
Before configuring a Console server you must select all the Console Server types 
physically connected to the system, this is done in the Settings part of the menu 
and is explained in section 
 
14.3 on page 92. 
To configure a Console server: 
1.  Click 
 or Console Servers from the menu. The 
Console Servers page appears.