AccessIT 
98
 
15.4 Replication 
You can add a secondary AccessIT Manager unit to the system. The primary unit 
then replicates all data to the secondary unit. In the event of a failure in the 
primary unit, the secondary unit can take over, and operate with the most up to 
date database.  
15.4.1 Connecting the secondary unit to the network 
1. 
Connect the secondary unit to a power supply outlet. 
2. 
Connect the secondary unit to the network as follows: On the rear panel 
connect an Ethernet cable to LAN 1 
3. 
Power up the secondary unit. 
15.4.2 Configuring the secondary unit 
Configure the secondary unit before configuring the primary unit. Configuration 
involves changing the secondary unit IP address, (so as not to cause a network 
conflict by having the same IP address as the primary unit) and assigning the unit 
to be the secondary unit. 
1.  From the secondary unit login to the AccessIT Manager web interface. See 
section 
 
5 on page 19 to display the AccessIT Web interface. 
2.  Change the IP address of the secondary unit to be different to the primary unit, 
but ensure that it resides on the same network segment. You change the 
secondary unit IP address from the Network tab under Settings/Unit 
Maintenance. See section 
 
16.2 on page 106. Once changed, the unit restarts. 
3.  Login again with the new network settings. 
4.  From the Settings/Maintenance menu, click Replication, Figure 90 appears.