U3585-J-Z125-8-76
281
SM2 reports
PCS report
SQPLN (%)
System performance percentage planned for this category.
(This variable is irrelevant for the SUM category and is therefore
replaced by blanks.)
SQACT(%)
Current percentage of system performance for this category
RDACT
Current delay of all jobs in this category.
If no dilation was sensed, ’**’ is output (see section on “dilation
factor” on page 447 of the glossary).
(A system-global value is given in the SUM line.)
DUR-RO (1/SEC)
Number of DURATION time slice runouts for tasks in this category.
(The given service rate has been used up, the task is placed in the
defined continuation category.)
DUR-RO-P (1/SEC)
Number of DURATION time slice runouts with preemption for tasks
or jobs in this category. (Meaning as above; since the defined
continuation category is not permitted because of overloading, the
task is entered in task queue 6.)
Note on SR2000