Black Box EncrypTight Enforcement Point (ETEP) Manual De Usuario

Descargar
Página de 88
Tamper Switch and Zeroization
ETEP Installation Guide
69
Figure 49
Correctly inserted and latched power supply is shown on the left. Note the 
position of the release levers. 
6 Replace the power supply bracket (
7 Insert the power cord in the replacement power supply.
8 Reconnect power supplies 1 and 2 to their respective power sources. 
9 Return the failed power supply to Black Box as directed by Customer Support. 
Tamper Switch and Zeroization
The following ETEP models include a tamper switch: ET0010A, ET0100A, ET1000A, and ET10000A. 
The switch is activated if the ETEP cover is removed while the unit is operating or if the ETEP detects 
that the cover is open while it is booting. When the ETEP detects that the switch is activated it enters an 
error state, zeroizes the appliance’s keying material, and discards all traffic. Zeroization has the same 
effect as issuing the filesystem-reset command.
The following events occur when the ETEP is zeroized:
Alarm LED illuminates
The ETEP sends a critical error trap 
The ETEP discards all packets that it receives on the local and remote ports
Ethernet management port communication is disabled. You will be unable to manage the ETEP using 
EncrypTight Manager.
CLI login is disabled via the serial port and Ssh
Data files are permanently deleted, including log files
The file system is reset to factory defaults
The zeroization process takes about 20 minutes to complete.