 Heavy Duty Edge Switches       Installation and User Guide(07/05) 
 
48
the LBHXXXA(E)-H’s power terminals, positive (+) and negative (-) screws. The use of Ground 
(GND) optional; it connects to the Edge Switch chassis. Ensure that each lead is securely 
tightened from the top, as shown on above picture with arrow.  
NOTE:  Always use a voltmeter to measure the voltage of the incoming power supply 
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead 
will connect to the post labeled “+ve” and the rest to the “-ve”. 
The GND can be hooked up at the last. 
When power is applied, the green PWR LED will illuminate. 
 
3.8  Connecting Ethernet Media 
The Black Box LBHXXX-Series Edge Switches can be connected to two media 
types i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and 100BASE-
FX only.  CAT 5 cables should be used when making 100BASE-TX connections. When the 
ports are used as 10BASE-T ports, CAT 3 may be used.  In either case, the maximum