Chapter 1      Unpacking and Installing the CSS
Installing the CSS 11050 or CSS 11150
1-6
Cisco 11000 Series Content Services Switch Hardware Installation Guide
78-15146-02
Concurrently, report the nature and extent of the damage to Customer Service. 
Report the problem or deficiency to Customer Service along with the model 
number and serial number. Upon receipt of this information, you will be provided 
with service instructions, or a Return Material Authorization (RMA) Number and 
shipping information.
Installing the CSS 11050 or CSS 11150
The CSS 11050 or CSS 11150 can be placed on a flat surface as a free-standing 
unit or rack-mounted in an equipment cabinet. The following sections describe the 
steps to install the CSS as a:
Free-standing unit
Rack-mounted unit
Prior to installing the CSS, observe the following installation requirements:
The ambient operating temperature is 32° to 104° F (0 to 40° C).
If you install the CSS in a closed or multi-unit rack, the operating ambient 
temperature of the rack environment may be greater than the room ambient 
temperature. Ensure that the temperature does not exceed the CSS maximum 
ambient operating temperature.
The minimum clearance requirement is 2 inches (10 cm) of air flow space on 
both sides of the chassis.
Ensure that the CSS is reliably grounded to earth. We recommend that you do 
not use power strips or extension cords to connect the CSS to the power 
source.
Caution
Do not remove the CSS 11050 or CSS 11150 cover. There are electrical shock 
hazards present in the unit if the cover is removed. There are no serviceable or 
installable components available with the CSS 11050 and CSS 11150.
Do not use a 3-prong to 2-prong electrical adapter. This will compromise the 
grounding.
Note
Removing the CSS 11050 or CSS 11150 cover voids its warranty.