Connecting Cisco ISDN PRI Network Modules to the Network
  Channelized T1/E1 PRI Network Modules with G.703
3
Connecting Cisco ISDN PRI Network Modules to the Network
 and 
 show the faceplates for the 1-port and 2-port channelized T1/E1 PRI network 
modules with G.703. 
Figure 1
1-Port Channelized T1/E1 PRI Network Module with G.703
Figure 2
2-Port Channelized T1/E1 PRI Network Module with G.703
Enabling Wetting Current on Channelized T1/E1 PRI Network Modules with 
G.703
Wetting current is a small amount of electrical current (60 to 140 milliamps) sent from the central office 
to the card to prevent the corrosion of electrical contacts in the module network connection.
The wetting current feature can be enabled or disabled by the end user. It is controlled by the location of 
a jumper on the J8 (CTLR 0) and J9 (CTLR 1) connectors on the network module. (See 
.)
To enable the wetting current feature, connect pins 1 and 2 on the J8 and J9 connectors with the jumper. 
To disable the wetting current feature, either remove the jumper completely, or use the jumper to connect 
pins 2 and 3 on the J8 and J9 connectors.
The card is shipped with the jumper connecting pins 2 and 3 on the J8 and J9 connectors, disabling the 
wetting current feature.
Cisco 3660
Yes
Yes
Cisco 37xx
Yes
Yes
Table 1
Modular Access Routers Supporting Cisco Channelized T1/E1 PRI Network Modules 
with G.703
Modular Access Router
NM-1CE1T1-PRI
NM-2CE1T1-PRI
RX
MON
NM-1CE1T1-PRI
EN
AIM
TX
MON
CD
LP
RA
LA
C0
CTLR 0
T1
E1-BAL
E1-UNBAL
82886
RX
MON
NM-2CE1T1-PRI
CD
LP
RA
LA
T1
E1-BAL
E1-UNBAL
EN
AIM
TX
MON
CD
LP
RA
LA
C1
C0
CTLR 1
CTLR 0
T1
E1-BAL
E1-UNBAL
82887