ViewSonic                                                40                                                PJ513D/PJ513DB
Replacing the lamp
To reduce the risk of electrical shock, always turn the projector off and disconnect the 
power cord before changing the lamp.   
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes 
before replacing the lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution 
when removing lamp glass that has shattered into sharp pieces.
To reduce the risk of injuries to fingers and/or compromising picture quality by touching 
the lens, do not touch the empty lamp compartment when the lamp is removed.
This lamp contains mercury. Consult your local hazardous waste regulations to dispose 
of this lamp in a proper manner.
1.
Turn the power off and disconnect 
the projector from the wall socket. If 
the lamp is hot, avoid burns by 
waiting for approximately 45 
minutes until the lamp has cooled.
2.
Turn the projector over. Then loosen 
the screws on the lamp cover.
3.
Remove the lamp cover from the 
projector.
Do not turn the power on with the 
lamp cover removed.
4.
Remove the lamp cords from the slots.
5.
Disconnect the lamp connector by 
pushing it against the projector while 
pulling it up.
6.
Loosen the screw that secures the 
lamp.
7.
Lift the handle so that it stands up. 
Use the handle to slowly pull the lamp 
out of the projector.
Pulling it too quickly may cause the 
lamp to break and scatter broken 
glass in the projector.
Do not place the lamp in locations 
where water might splash on it, 
children can reach it, or near 
flammable materials.
Do not insert your hands into the 
projector after the lamp is removed. If 
you touch the optical components 
inside, it could cause color 
unevenness and distortion of the 
projected pictures.