NOTE(about overheating) When the internal temperature rises too high, POWER to the unit switches OFF as a safety 
precaution; the LED lamp indicator turns OFF.  Set the POWER switch to [0] and wait 20 minutes until the equipment has 
cooled sufficiently before continuing with operation.
Symptom
Before requesting repair, refer to the chart below. If the problem cannot be corrected, contact your 
dealer.   
Blinks/
Lights red
Lights red
Turns off
Lamp is not lit.
The interior of the equipment may be too hot. Switch POWER OFF, 
wait 20 minutes until the equipment cools, and check whether the 
ventilation openings are blocked, whether the air filter is dirty, or 
whether the ambient temperature exceeds 95°F (35°C). And switch 
POWER ON again. 
Replace the lamp if the same problem occurs again.
Blinks/
Lights red
Blinks red
Turns off
Lamp or lamp cover is not found, or hasn’t been fitted in correctly. 
Switch POWER OFF, and wait for 45 minutes until the equipment cools. 
Check fitting of the lamp and lamp cover, and switch POWER ON 
again. 
Contact your dealer if the same problem occurs again.
Blinks/
Lights red
Turns off
Blinks red
The cooling fan is not operating.
Switch POWER OFF, and wait for 20 minutes until the equipment cools. 
Check for foreign matter in the fan, and switch POWER ON again. 
Contact your dealer if the same problem occurs again.
Blinks/
Lights red
Turns off
Lights red
The interior of the equipment is too hot. See  NOTE: (about 
overheating) 
below.
Switch POWER OFF, and wait for 20 minutes until the equipment cools. 
Check whether the ventilation openings are blocked., whether the air 
filter is dirty, or whether the ambient temperature exceeds 95°F (35°C). 
Then switch POWER ON again. 
Contact your dealer if the same problem occurs again.
Lights green
Blinks red 
alternately 
with TEMP 
indicator
Blinks red 
alternately 
with LAMP 
indicator
The interior of the equipment is too cool. 
Check whether the ambient temperature is below 32°F (0°C). Contact 
your dealer if the same problem occurs when the ambient temperature 
is 32°F  ~ 95°F (0°C ~ 35°C).
Lights green
Blinks red 
synchronizing 
with TEMP 
indicator
Blinks red 
synchronizing 
with LAMP 
indicator
The air-filter has been used for 100 hours or more.
Clean the filter, then reset the filter timer.
Table 12: Symptom 
Symptom
Possible cause
Remedy
Page
No power
The main POWER switch 
is not turned on.
Turn on the main POWER switch.
page 9
The power cord is 
disconnected.
Plug the power cord into an AC power outlet.
page 7
No video or 
audio
The Input is not correctly 
set.
Use INPUT button on projector control pad or remote control 
to select input source.
page 10
No signal input.
Connect correctly.
page 7,8
Table 11: Indicator Messages  (Continued)
POWER
indicator
LAMP
indicator
TEMP
indicator
Meaning or Action Required