Viewsonic PJ1172 Manual De Usuario

Descargar
Página de 54
ViewSonic  PJ1172
41
Regarding The Indicator Lamps (continued)
STANDBY/
ON indicator
LAMP 
indicator
TEMP 
indicator
Description
Lighting in 
Red
Blinking in 
Red
Turned off
Either there is no lamp and/or lamp cover, or 
either of these has not been properly fixed.
Please turn the power off, and allow the unit to 
cool down at least 45 minutes. After the projector 
has sufficiently cooled down, please make confir-
mation of the attachment state of the lamp and 
lamp cover, and then turn the power on again.
If the same indication is displayed after the treat-
ment, please contact your dealer or service com-
pany.
Lighting in 
Red
Turned off Blinking in 
Red
The cooling fan is not operating.
Please turn the power off, and allow the unit to 
cool down at least 20 minutes. After the projector 
has sufficiently cooled down, please make confir-
mation that no foreign matter has become caught 
in the fan, etc., and then turn the power on again.
If the same indication is displayed after the treat-
ment, please contact your dealer or service com-
pany.
Lighting in 
Red
Turned off Lighting in 
Red
There is a possibility that interior portion has 
become heated.
Please turn the power off, and allow the unit to 
cool down at least 20 minutes. After the projector 
has sufficiently cooled down, please make confir-
mation of the following items, and then turn the 
power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treat-
ment, please change the lamp by referring to the 
section “Lamp”.
Lighting in 
Green
Alternative Blinking in 
Red
There is a possibility that interior portion has 
become overcooled.
Please use the projector within the usage temper-
ature parameters (0°C to 35°C). After the treat-
ment, resent the power to on.
Lighting in 
Green
Simultaneous Blinking 
in Red
It is time to clean the air filter, or there is no air 
filter.
Please immediately turn the power off, and clean 
or change the air filter by referring to the section 
“Air Filter”. After cleaning or changing the air filter, 
please be sure to reset the filter time. After the 
treatment, resent the power to on.