JVC RS-232C Manual De Usuario

Descargar
Página de 20
JVC D-ILA Projector Remote Control Guide 
Page 12 of 20 
Acknowledgement Response Return Codes - Advanced 
 
For some functions, it is possible to obtain a more detailed response from the projector. This 
is useful where different actions are required depending on the current projector settings or 
status. To request the detailed response, taking the above example of the Power Command, 
send to the projector: 
 
3F 89 01 50 57 0A 
 
If  the  projector  receives  the  enquiry  command,  as  a  confirmation  that  it  has  received  the 
command, it will first respond with exactly the same information as that returned by the basic 
Acknowledgement Return Code shown on page 11: 
 
06 89 01 50 57 0A 
 
Next, the projector will send the detailed response. It will send: 
 
40 89 01 50 57 RR 0A – Where RR is the Detailed Response Return Code. 
 
For  clarity,  the  two  returned  responses  are  separated  here.  In  practice,  they  are  returned 
from the projector as one continuous string. 
 
For  the  Power  Status  Enquiry, the  possible  values for  the  Detailed  Response  Return  Code 
status (RR) are: 
 
30 – Standby 
31 – Power On 
32 – Cooling 
34 – Emergency 
 
So, as a full worked example, if we send to the projector: 
 
3F 89 01 50 57 0A 
 
If the projector were currently cooling down after being switched to Standby, it would return: 
 
06 89 01 50 57 0A 40 89 01 50 57 32 0A 
 
If the projector were on Standby, it would return: 
 
06 89 01 50 57 0A 40 89 01 50 57 30 0A 
 
A list of all of the useful enquiry codes, together with all possible detailed responses is below: 
 
Power Status (to confirm the current Power Status) 
Enquiry Command (to projector) 
3F 89 01 50 57 0A 
Response (from projector) 
06 89 01 50 57 0A 40 89 01 50 57 RR 0A 
 
 
Response (RR) 
Meaning 
30 
Standby 
31 
Power On 
32 
Cooling 
34 
Emergency