Command Format 
 
The RS-232C commands are bidirectional and consist of a variable number of hexadecimal 
numbers. All of the commands sent to the projector shown in this guide are either 7 bytes or 
10  bytes  long.  The  Acknowledgement  Response  Return  Codes  returned  from  the  projector 
can be between 6 and 14 bytes long. The basic format of the commands is as follows: 
 
Section 
Size 
Comments 
Header 
1 byte  
Can be one of four possible values – see below 
Unit ID 
2 bytes  
Fixed – always 89 01 
Command 
2 bytes 
See below 
Data  
Variable 
Length varies depending on command – see below 
End  
1 byte.  
Fixed – always 0A 
 
Taking each of these sections in turn: 
 
Header 
The header can be one of 4 possible values. These are: 
21 – Operating Command (from PC/controller to projector) 
3F – Acknowledgement Response return Code Request (from PC/controller to projector) 
06 – Acknowledgement Response Return Code – Basic (from projector to PC/controller) 
40 – Acknowledgement Response Return Code – Detailed (from projector to PC/controller) 
 
Unit ID 
This is fixed at 89 01 for all models. 
 
Command  
This is the command sent to/from the projector and varies depending on the command. As 
an  example,  the  Power  Command  is  50  57.  The  other  commands  can  be  worked  out from 
the tables on pages 3-9. 
 
Data 
This is the value to apply to the command. Using the Power example above, the data value 
for Off is 30 and the data value for On is 31. 
 
End 
This signifies the end of the command and is fixed at 0A for all models. 
 
Putting all this together, a typical command (Power On) to the projector would therefore be: 
 
Header 
Unit ID 
Command 
Data 
End 
21 
89 
01 
50 
57 
31 
0A 
 
Error Handling 
The  projector  will  ignore  any  commands  that  it  cannot  recognise,  e.g.  Unit  ID  does  not 
match,  parity  error,  invalid  command,  etc.  It  will  also  ignore  any  inappropriate  commands, 
e.g. Power On when in cooling mode. 
 
The projector will discard any commands received if there is a break of 50ms or longer in the 
incoming data. 
 
If consecutive commands are used, it is assumed that any external controller will not transmit 
a command until it has received an appropriate Acknowledgement Response Return Code to 