Crestron electronic CP-X3014WN/ Manual De Usuario

Descargar
Página de 70
64
Command Format
Command formats differ among the different communication ports.
●  TCP #23 
You can use the RS-232C commands without any changes. The reply data 
format is the same as the RS-232C commands. (
RS-232C Communication 
in the Operating Guide - Technical
However, the following reply will be sent back in the event of authentication 
failure when authentication is enabled.
Header
Data length
RS-232Ccommand
Check Sum
Connection 
ID
0x02
0x0D
13 bytes
1 byte
1 byte
Reply
Error code
0x1F
0x04
0x00
<Reply in the event of an authentication error>
Header → 
0x02, 
Fixed
Data length 
→  RS-232C commands byte length (0x0D, Fixed)
RS-232C command  →   RS-232C commands that start with 0xBE 0xEF  
(13 bytes)
Check Sum 
→   This is the value to make zero on the addition of the 
lower 8 bits from the header to the checksum.
Connection ID 
→   Random value from 0 to 255 (This value is attached 
to the reply data)
●  TCP #9715
Send Data format
The following formatting is added to the header (0 x 02), Data length (0 x 0D), 
Checksum (1 byte) and Connection ID (1 byte) of the RS-232C commands.
7. Other Functions
7.4  Command Control via the Network (continued)