Summit HL-630 OPC Manual De Usuario

Descargar
Página de 46
 
26
 
 
 
 
Okidata OL-400e OPC 
Okidata OPC Cartridge Part # 56116801 
OEM Stated Yield: 20,000 
(The procedure for these machines is the same as 
used for the Okidata OL-1200, OP-20) 
 
Turn off the printer 
While holding the MENU1/MENU2 button down, 
turn the printer back on. Keep holding the button 
down until you see USER MNT on the display 
panel. Release the button. 
Press the MENU1/MENU2 button three times. The 
display will read DRUM CTR RESET. 
Press the ENTER button. The display will read 
WARMING UP, and finally ON LINE.  
The counter is reset! 
 
OL-600e/610e
 
Okidata OPC Cartridge Part #  56116801 
OEM Stated Yield: 20,000 
(The procedure for these machines is the same as 
used for the Okidata OP-6e, OL-600e, OP-10e, and 
OP-14e) 
 
From the computer the printer is directly hooked up 
to, enter the Printer Status Monitor.  
Click on the “Settings” Tab.  
Under “Reset Item” click “Drum Count”, and then 
“Reset”. 
The Counter is reset! 
 
OkiPage 6e
 
Okidata OPC Cartridge Part #  56116801 
OEM Stated Yield: 20,000 
(The procedure for these machines is the same as 
used for the Okidata OP-6e, OL-600e, OP-10e, and 
OP-14e) 
 
From the computer the printer is directly hooked up 
to, enter the Printer Status Monitor.  
Click on the “Printer Menu” tab.  
Click on the “Maintenance” tab.  
Click on the “Drum Counter Reset” tab. 
The Counter is reset! 
 
 
OkiFax 1000/1050/5300/5400/5600/5650
 
Okidata OPC Cartridge Part #  56116901 
OEM Stated Yield: 20,000 
(The procedure for these machines is the same as for 
the OP-4W, and the OP-8W) 
 
Wait until the time, date and answering mode appear 
on the display. Then press the Select Function key. 
Press the 7/Counter Display One Touch Key. The 
display shows Drum Count. 
Press the Yes (left arrow) key to clear the counter 
Press the select Function key to finish. 
The Counter is reset 
OkiFax 2400/2600
 
Okidata OPC Cartridge Part #  56116901 
OEM Stated Yield: 20,000 
 
Unlike most of the other Okidata printer/Fax 
machines, there is also a counter that must be reset 
for the toner cartridge! The following information 
will allow you to reset the Toner, Drum, Machine, 
and the fuser page count. Okidata strongly 
recommends that the Machine Page Count, and the 
Fuser Page Count be left alone. 
 
Wait until the time, date and answering mode appear 
on the display. Then press the “Select Function” key. 
Press the “28/Print Counter” key. This first counter 
is the Machine Page Count. Leave this counter 
alone! Press the “Yes/Left Arrow” key. The page 
count of the toner cartridge will show on the display. 
To reset the Toner Count press the “Right 
Arrow/No” key. To bypass this counter, press the 
“Yes/Left Arrow” key. If you pressed the “No” key, 
the display will say “Toner Count Clear?” Press the 
“Yes/Left Arrow” key. Then “Are You Sure?” will 
display. Press the “Yes/Left Arrow” key again to 
reset the toner count.   
 
The next counter that will display is the Drum 
Count. If you have just replaced the drum cartridge 
and need to reset the drum counter, Press the “Right 
Arrow/No” key. The display will ask if you want to 
clear the counter. Press the “Yes/Left Arrow” key 
twice. If you only wish to view the drum count 
without resetting it, press the “Yes/Left Arrow” key 
instead of the “No” key. The next counter to show 
on the display is the Fuser. Press the “Select 
Function” key to return to the standby mode.