Star Micronics 150 Manual De Usuario
Programmer's Guide
PcOS Series 150
Control Codes
Summary by Function
12/14/99
Rev G
Page 85
Control Codes Summary by Function
Normal
ASCII
ASCII
Second
ASCII
field
ASCII
field
Hex Code
IPCL equivalent
code
code
Description
Page
Print/paper motion
[CR]
0DH
&%CR
Set carriage return.
15
Vertical motion
[LF]
0AH
&%LF
Set line feed.
15
[VT]
0BH
&%VT
Set vertical tabs.
20
[FF]
0CH
&%FF
Set form feed.
20
[ESC]
0
1BH,30H
&%ST
Set 1/8-inch line space.
18
[ESC]
1
1BH,31H
&%SG
Set 7/72-inch line space.
19
[ESC]
2
1BH,32H
Begin variable line spacing.
(Enable [ESC] A n).
(Enable [ESC] A n).
19
[ESC]
3 <n>
1BH,33H
&%SV
<m
<m
1
><m
2
><m
3
>
Set fine line space n/216 inch where
n=1..255 defines the feed used by
line feed.
n=1..255 defines the feed used by
line feed.
18
[ESC]
4
1BH,34H
&%ST
Set top of form.
20
[ESC]
5 <n>
1BH,35H
&%CA {n=0}
&%MA {n=1}
&%MA {n=1}
Set auto line feed.
n=0 end
n=1 begin
n=0 end
n=1 begin
21
[ESC]
A <n>
1BH,41H
Set variable line spacing n/72 where
n=1..85 is enabled by [ESC] 2.
n=1..85 is enabled by [ESC] 2.
19
[ESC]
B
<n>
<n>
1
<n>
2
<n>
3
...
<n>
k
<0>
1BH,42H
Set vertical tabs at lines n
1
n
2
...
n
k
0.
20
[ESC]
C <n>
1BH,43H
&%
Set form length in lines or inches.
21
[ESC]
J <n>
1BH,4AH
&%FM
<m
<m
1
><m
2
><m
3
>
Do a fine line feed n/216 inch.
n=0 no line feed
n=1..255
n=0 no line feed
n=1..255
18
[ESC]
R
1BH,52H
&%HV
Reset horizontal and vertical tabs to
defaults.
defaults.
17
[ESC]
]
1BH,5DH
&%LR
Reverse line feed.
21
[ESC]
d <n>
1BH,64H
&%FL
<m
<m
1
><m
2
>
Feed <n> lines at the current
spacing.
spacing.
19
Horizontal motion
[HT]
09H
&%HT
Set horizontal tabs.
16
[ESC]
D
<n>
<n>
1
<n>
2
<n>
3
...
<n>
k
<0>
1BH,44H
Set horizontal tabs at columns n
1
n
2
... n
k
0. The maximum value of n
depends on the station selected.
16
[ESC]
R
1BH,52H
&%HV
Reset horizontal and vertical tabs to
defaults.
defaults.
17
[ESC]
V <n>
1BH,56H
Set intercharacter spacing.
32
[ESC]
X
<n
<n
1
><n
2
>
1BH,58H
Set left and right margins.
n
n
1
=left in characters
n
2
=right in characters
[ESC]
a <n>
1BH,61H
&%JR
&%JC
&%JL
&%JC
&%JL
Set justification.
n=0 left
n=1 center
n=2 right
n=4 180
n=0 left
n=1 center
n=2 right
n=4 180
°
right
n=5 180
°
center
n=6 180
°
left
180
°
mode not available in IPCL.
17