Citizen iDP-3210 Manual De Usuario

Descargar
Página de 67
iDP-3210 User’s Manual
   
 
                                                                            34/67
  CITIZEN
6.1.3 I/O SIGNALS
      (1) Input Signals to the Printer
 DATA
: 8-bit parallel signal (positive logic)
 STB
: Strobe signal to read 8-bit data (negative logic)
 RESET : Signal to reset the entire printer (negative logic) 1m sec or more
       (2) Output Signals from Printer
 ACK 
: An 8 bit data request signal. Pulse signal output at the end of the BUSY signal. (negative logic)
 BUSY
: The signal to indicate BUSY state of the printer.  Input new data for "LOW". (positive logic)
 FAULT : The signal which is made "LOW" when the printer is in alarm state. All the control circuits inside
the printer are stopped at this time.(negative logic)
 PE
: The signal which is output when paper runs out or goes scarce. (positive logic)
 Drawer Switch Output: With the switch open, this signal goes "HIGH".  When shorting, this goes "LOW".
      (3) Power supply
 +5 V DC
: This is 5V pulled up by a 3.3k
Ω
 resistor.
 GND
: This is the common ground for the circuit.
idp-3210 User's Manual