Citizen PPU-231 Manual De Usuario

Descargar
Página de 100
PPU-231 User’s Manual
 
 28 
CITIZEN
 
6.3 
Input and Output Signals 
6.3.1 
Input and Output Signals   
(1)  Input signals to the printer 
• DATA 
:  8-bit parallel signal (Active: “High”) 
• STROBE  :  Strobe signal to read the 8-bit data (Active: “Low”) 
• RESET 
:  Signal to reset the entire printer (Active: “Low”); 1 ms or more   
(2)  Output signals from the printer 
• ACK 
:  8-bit data request signal.    A pulse signal to be output at the end of the BUSY signal   
(Active: “Low”) 
• BUSY 
:  Signal to indicate that the printer is busy.    Input new data when it is "Low." 
(Active: “High”) 
• FAULT 
:  Turned to "Low" when the printer has an alarm.    At this time, all the control circuits in 
the printer stop. (Active: “Low”) 
• PE 
:  Output if the printing paper has run out or is running out. (Active: “High”)